Monitors & AlarmsSelecting a system

Connection Choices for the Power Outage Alert System

What Is the Power Outage Alert System?

The Power Outage Alert System is an add-on compatible with all EverSafe battery-powered backup generator models.

In the event of a power outage, the alert system will automatically call up to four pre-set phone numbers when either:

  • The backup generator loses incoming utility power.
  • The generator ceases to supply power (i.e., batteries are drained).

It can also:

  • Report the ambient room temperature when the alert is triggered.
  • Allow custom alert messages—useful especially for facilities that have units in different locations.

How the Alert System Handles Calls

To send or receive calls, this system must be linked via its phone jack to a phone line or network. You generally have three connection methods:

  1. Standard Analog Phone Line (POTS) – Regular landline.
  2. Voice-over IP (VoIP) Adapter – Via wired or Wi-Fi internet networks.
  3. Wireless Cellular Adapter (Mobile Hotspot) – Using cellular network service.

How well each works depends on:

  • Your facility’s existing phone/internet infrastructure.
  • IT/technical capability.
  • Whether phone or internet services remain reliable during an outage.

1. Using a Standard Phone Line

Also called a “copper line” or POTS (Plain Old Telephone Service), this is the default and most reliable choice. In emergencies, traditional landlines often continue to work because they’re powered independently of your main electrical supply.

Setup is simple: plug one end of the phone cord into the alert system, and the other into the wall jack. No additional adapters are required.

2. Using VoIP

If your location uses modern telecom systems without traditional phone wiring, VoIP may be used. However, since the alert system expects an analog interface, a VoIP adapter is needed to convert digital/internet signals into analog ones.

Two common setups:

  • Wired VoIP: The adapter plugs into an Ethernet port; the alert system connects via a phone cable to that adapter.
  • Wireless VoIP: Adapter connects to your Wi-Fi; the alert system still uses a phone cable to the adapter.

Caveats: VoIP depends on internet connectivity and power. If the internet or power fails, VoIP may also fail, making it less reliable than analog in some emergency scenarios.

3. Using a Cellular Hotspot

This option uses wireless cell-network service via a mobile hotspot. You connect the alert system to the hotspot using a phone cable, and the hotspot provides the cellular network connection.

Pros:

  • Cellular networks often maintain service during power outages (cell towers tend to have backup power).
  • It can serve as a fallback for locations without reliable landlines or internet.

Cons:

  • The hotspot needs its own power—many users draw that from the EverSafe backup generator.
  • Signal strength may vary (especially in rural or remote areas), which could affect performance.
  • Requires a SIM card and active service plan from a carrier (note: EverSafe does not supply the carrier plan).

How to Order a Remote Monitoring / Alert-Capable System

EverSafe builds each system to match your facility’s unique requirements in terms of features, connectivity, and monitoring. To configure a backup generator with alert or alarm add-ons, or to get a quote, contact EverSafe’s product and technical team:

Phone: 1-800-765-3237 (Monday-Friday, 8:30 AM to 5:00 PM EST)

Share this article

Further Reading

Case Study: Adapting a Two-Hour Backup Power Plan for an Operating Room in Virginia 
Surgery Centers

Case Study: Adapting a Two-Hour Backup Power Plan for an Operating Room in Virginia 

An operating room project in Virginia needed two hours of battery backup power for designated equipment. As construction progressed, the company identified additional equipment needing protection, and the backup power plan needed to reflect those requirements.  Medi-Products worked with the project team to review equipment specifications and electrical drawings, adjust the system sizing, and develop […]

Read more
Can One Battery Backup System Power Multiple Refrigerators and Freezers? 
Healthcare ComplianceRefrigerated Medications

Can One Battery Backup System Power Multiple Refrigerators and Freezers? 

A pharmacy may have two vaccine refrigerators and a freezer. A laboratory might need backup power for cold storage, incubators, and supporting equipment. Does every device need its own battery backup system?

Read more
Which Battery Backup System Will Work With My Vaccine Refrigerator, Pharmacy Fridge, or Laboratory Freezer? 
Refrigerated MedicationsVaccine Storage

Which Battery Backup System Will Work With My Vaccine Refrigerator, Pharmacy Fridge, or Laboratory Freezer? 

Choosing battery backup for cold storage starts with the equipment you need to protect. A vaccine refrigerator, pharmacy fridge, and laboratory freezer may have different electrical requirements, even when they look similar or occupy the same amount of space.  The right system must match the equipment’s electrical specifications, handle its startup demand, and provide enough […]